Enphase IQ Battery 5P: Gateway Resistor Requirement Explained

Understanding the 120-ohm resistor requirement for Enphase IQ Battery 5P and Gateway communication. Ensures stable CAN bus operation in residential solar.

Frequently Asked Questions

What is the correct procedure for measuring the CAN bus termination resistance?

Disconnect power from both ends of the CAN bus (battery and gateway). Use a multimeter set to ohms (Ω) and measure the resistance between the CAN_H and CAN_L wires at the gateway connection. It should read approximately 120 ohms if properly terminated.

What type of cable is recommended for the CAN bus connection between the Enphase IQ Battery 5P and the Gateway?

Enphase recommends using shielded twisted pair cable specifically designed for CAN bus applications. The cable should meet or exceed the specifications outlined in the Enphase installation manual.

What happens if the CAN bus termination resistor is missing or has the wrong resistance value?

A missing or incorrect termination resistor can cause signal reflections on the CAN bus, leading to data corruption, communication errors, and intermittent system failures. The system may exhibit unstable SOC readings or fail to respond to grid events.

Related questions

Loading related questions...

Marcus leads the technical research department at Storage Faults. Together with a team of systems analysts, he specializes in translating complex solar storage error codes into actionable diagnostic steps for the US market.